Regqueryvalueex is unsuccessful for software microsoft sms task sequence smstsendprogram

Its not possible to select a task sequence that contains a boot image reference. Configmgr use download package content task sequence step. Good day, when running the osd after selecting the ts that will be used, the checking dependencies step runs and then the pc reboots. Oct 16, 20 a very important clue is that the sms task sequence agent is still running. Regopenkeyexw is unsuccessful for software\microsoft\sms\task sequence tsbootshell 11172016 11. May, 2016 regopenkeyexw is unsuccessful for the software microsoft sms task sequence.

Sccm task sequence hangs on installing solutions experts. The situation that brought it to my attention was that i was trying to run a powershell script as part of the sequence. It queries sccm to find out what domain a computer is in. Dec 17, 2018 once you find out the location of smsts log file, the next step is to open it and check for the errors. Client machines may fail to boot into pxe if system center configuration manager service pack 2 has been applied. Deploy applications in task sequence configuration. Mar 04, 2016 i mean that the task sequence appears to hang or at least the mechanism that reports back to software center that its done. At the very end there is an error regqueryvalueexw is unsuccessful for software \microsoft\sms\task sequence, smstsendprogram which may.

Windows 10 task sequence fails configuration manager 2012. Configmgr 2012 standalone media machine boots into. Detailed information on sms task sequence agent service. If there are one or two computers which are in front of you,you can check press f8 and see what happens by looking at smsts. Microsoft further disclaims all implied warranties including, without limitation, any implied warranties of merchantability or of fitness for a particular purpose. Click on the determine local or remote userstate task and then go to add general set task sequence variable. You could bring up command prompt by pressing f8 key during osd. In sccm, create a status filter rule by going to site database site management primary site site settings status filter rules. From the smsts log i get the regqueryvalueexw is unsuccessful for software\microsoft\sms \task sequence, smstsendprogram entry, but dont know what to do to resolve. Configmgr 1511 cannot connect to a sql server that. Advertised sccm os deployment task sequence does not pxe boot. Try and use the win pe driver instead of the proper i tried that and then it didnt even make it to the network stage without failing so seems i need the driver. Once you find out the location of smsts log file, the next step is to open it and check for the errors.

Regqueryvalueexw is unsuccessful for software\microsoft\sms\task sequence, smstsendprogram and failed to open key software\microsoft\sms. Regopenkeyexw is unsuccessful for software \ microsoft \ sms \ task sequence tsbootshell 11172016 11. With the standard client task sequence and the caption selected after choosing the task, the system was reloaded with windows 7. This package does not require a program and will only be used to provide the content during the task sequence. Certain machines fail to register in sccm correctly. From your logs, there are access issues with the registry. A system center configuration manager 2007 sp2 task sequence. Mastering the fundamentals by kent agerlund, and in it, there is a refresh to win 7 from xp lab using mdt integraated with config manger. Bc smbios guid0000001149188015bf5a888888888788 device. Mdt deployment white summary screen software deployment. Jul 12, 20 for example, imagine you have a brand new machine with the same smbios guid as an existing machine, if you have an os task sequence advertised to this machines mac address only as a direct collection membership, when your machine pxe boots, the order of events are. Aug 27, 2010 i tried this on our central sccm server and i still got the error, i then realised that the sms provider sql db was on a separate server so i did the same action restarted the wmi service, which in turn will restart the sms agent host service on that server, and as soon as i had the two services started again, all was good. The task sequence is quite simple, we partition the disk and apply the os, apply. If you forgot where to find it or too lazy to look its location on internet, this small vbs script will locate it directly for you.

Once you are there find the sccm thread you wanted to restart. I have a vbscript which works abolultuly fine on my workstation. The sample scripts are provided as is without warranty of any kind. My applications are set to silently install, whether or not a user is logged in. The one an only step in the task sequence is called hp bios config wol and bios wakeup where a command line command is run.

Right click on the affected task sequence and choose edit. Most the things in my searching say like verify network, access account. In the run task sequence step, its as simple as browsing to the task sequence and selecting it. May 01, 2014 ran configure configmgr integration tool as administrator to remove existing mdt extensions and got this when i tried to proceed. Ran configure configmgr integration tool as administrator to remove existing mdt extensions and got this when i tried to proceed. The boot image reference has to be on the parent task sequence. With the sysprep and capture task sequence, the capture failed immediately. I pxe booted that pc with the litetouch wim i created in mdt and then ran the task sequences.

You might be receiving any one of the following errors. It is difficult to troubleshoot the machines where the task sequenceos deployment failed remotely. Sccm osd task sequence problem resolved ars technica. Sms task sequence agent is a windows 7 service that sms client agent for task sequence execution sms task sequence agent service is provided by. Jan 11, 2019 when running the osd after selecting the ts that will be used, the checking dependencies step runs and then the pc reboots. Occasionally, i will get a white screen for the summary. Im following the instructions exactly, but everytime i run the task sequence to i. I tried this on our central sccm server and i still got the error, i then realised that the sms provider sql db was on a separate server so i did the same action restarted the wmi service, which in turn will restart the sms agent host service on that server, and as soon as i had the two services started again, all was good.

Does your install account have administrator access. New sccm instance and task sequence is bombing out. A very important clue is that the sms task sequence agent is still running. I mean that the task sequence appears to hang or at least the mechanism that reports back to software center that its done. Mid march, i create a scheduled task on my configmgr server to, once every hour, invoke a powershell script that send a wakeonlan to all active but offline desktops. This post will provide some guidance how to get the most out of this site. Certain machines fail to register in sccm correctly edugeek. Let the compiler add it based on your project settings. Just started getting a problem when migrating xp users to win7. Pending osd regqueryvalueexw is unsuccessful for software.

And how is sms task sequence agent service related to tsmanager. By continuing to use this site andor clicking the accept button you are providing consent quest software and its affiliates do not sell the personal data you provide to us either when you. Weve come up with a good way of sending an email outlining task sequence completion status. This should create a set task sequence variable task after determine local or remote userstate task but before the request state store task. Importing configmgr 2007 task sequences xml to configmgr. Then use the cmtrace command to bring up the log viewer. However, having researched these errors i still dont have a fix. Windows 7 services sms task sequence agent tsmanager. Regopenkeyexw is unsuccessful for software \ microsoft \ sms \ task sequence tsbootshell 72017 10. Task sequence manager execution terminated as system shutdown is in progress. Logregqueryvalueexw is unsuccessful for software\microsoft\sms\task sequence, smstsendprogramlog.

Advertised sccm os deployment task sequence does not pxe. Hklm\software\wow6432node\microsoft\sms\mobile client\software distribution\state\paused and. We would like to show you a description here but the site wont allow us. Disclaimer the sample scripts are not supported under any microsoft standard support program or service. From the smsts log i get the regqueryvalueexw is unsuccessful for software\ microsoft\sms\task sequence, smstsendprogram entry, but. Regqueryvalueexw is unsuccessful for software\microsoft\sms\task sequence, smstsendprogram tsmanager 822016 10. The situation that brought it to my attention was that i was. When i run it as part of the task sequence, it fails. There are no task sequences available for this computer workaround.

Hklm\ software \wow6432node\ microsoft \ sms \mobile client\ software distribution\state\paused and. Ts could refer to terminal services, task sequence, typed smalltalk, or any number of things without the right context. How to restart sms executive threads like cloud user sync. Your code is mixing tchar and char types, and using wide function calls. The installation of config manager and all subsequent parts of the task sequence never run after the reboot, its like the task sequence ends there however the task sequence, shows the step of. Sms task sequence agent is a windows 7 service that sms client agent for task sequence execution sms task sequence agent service is provided by tsmanager. Evening all, we have about 20 out of about 500 machines that have the same issue where they will build missing programs sometimes and join the domain but no device shows up for it in sccm. A system center configuration manager 2007 sp2 task. Even stranger is they will show up in ad but doing an ad discovery to add it fails as well even though it picks up other non sccm devices. Jul 21, 2017 a relatively new feature that is available with configmgr is the ability to download the content of a package during a task sequence. Can you provide some more information as to your problem please. Hello all, what i am trying to do is use sccms own osd task sequence windows pe to deploy an operating system that boots using vhd native boot. Regopenkeyexw is unsuccessful for software\microsoft\sms\task sequence tsbootshell 72017 10.

Im having random issues with my deployments for windows 10. Mar 14, 2016 if you find that your system center configuration manager 1511 site server cant connect to your sql server, check for entries that resemble the following in both the smsexec. Dec 11, 2017 in the task sequence editor, select add general run task sequence. You may be having trouble deploying an operating system to a brand new machine even after you have advertised an os deployment task sequence to its correct mac address. Up until now the usmt task sequence has worked fine and ive used it to migrate several users. Once exported, open the zip file and navigate to the task sequence folder and copy out the object.

Certain machines fail to register in sccm correctly evening all, we have about 20 out of about 500 machines that have the same issue where they will build missing programs sometimes and join the domain but no device shows up for it in sccm. However it would be cool to copy the smsts log file during the task sequence failure. Configmgr 2012 standalone media machine boots into task. Feb 08, 2012 this problem occurs because of a pxe cache limitation of 1 hour if system center configuration manager 2007 service pack 1 sp1 has been upgraded to sp2 after the hotfix that is described in kb 9691 has been applied in a configuration manager 2007 sp1 environment. Feb 20, 2017 im having random issues with my deployments for windows 10. Each time this script runs, for each machine that is targeted, a. A relatively new feature that is available with configmgr is the ability to download the content of a package during a task sequence. In the task sequence editor, select add general run task sequence.

988 109 49 395 1490 1413 817 1070 1071 1318 872 711 601 1035 81 21 1305 1036 261 341 751 448 1599 1584 191 987 397 845 267 1629 1020 372 433 1063 686 1483 1020 245 1271 38 513 669 308 1334 434 572